1. Automatically
complete second pressure drop of three-phase three
wire and three-phase f-
¡¡ our wire voltage transformer
through wireless ways, not like normal way that
needs to p-
¡¡ lace a long voltage measure
line between tester and far-end of tested device,
so that a-
¡¡ void unnecessary short
circuit failure caused by long line that is the
problem should be
¡¡ avoided by transformer.
Moreover, sometimes this line need to cross roads,
it will be d-
¡¡ amaged if there is nobody
guarding it. Wireless second pressure drop device
avoids this
¡¡ situation effectively
and it is able to calculate rate ratio, angle error
and integrati-
¡¡ ve error of three phase
automatically.
2. Able to check automatically and save test errors
caused by testing wire under kinds of
¡¡ wire connection, and
calibrate them in later test automatically.
3. This device has a special design that is software
calibration function.It can realize a-
¡¡ ccuracy calibration no
need of hardware adjustment,also can be used in
field test in all
¡¡ levels of electricity
test and research department.
4. This tester has inner chargeable battery units
with large capacity. When in outside pla-
¡¡ ces without 220V AC electric
source, the inner battery unit is able to provide
electric-
¡¡ ity for this device.
The battery itself is charged by its inside quick
speed charger.
5. The left electricity will be showed in percentages,rather
than just giving a simple alarm.
6. Large screen, high-brightness liquid crystal
display,¡¡English menu and
operation instru-
¡¡ ction to realize friendly
communication with machine. Touchable key-press
makes operation
¡¡ easier. The wide liquid
crystal display has brightness adjustment and it
is able to be r-
¡¡ egulated according to
different seasons.
7. Users are able to print the test data any time
through micro-printer.
8. This device has saving function, able to save
200 units of test data. |
 |
1. Use environment
¡¡ ambient temperature:
£º-10¡æ¡« 40¡æ
¡¡ relative humidity£º ¡Ü80%
2¡¢measurement accuracy:
¡¡ The measurement accuracy
of this device is ¡À1%.
¡¡ rate ratio£º¦¤f =¡À£¨1%¡Áf+1%¡Á¦Ä+0.01£©£¨%£©
¡¡ angle accuracy£º¦¤¦Ä=¡À (1%¡Áf+1%¡Á¦Ä+0.1)£¨¡¯£©
¡¡ electric conductance£º
G=¡À (1%¡ÁG+0.01) mS
¡¡ electric susceptance£º
¦Ä=¡À (1%¡Á¦Ä+0.01)mS
¡¡ load£º S=¡À (1%¡ÁS+0.1)VA
¡¡ resistor£º R=¡À (1%¡ÁR+0.1)¦¸
¡¡ electric reactance£º X=¡À
(1%¡ÁX+0.1)¦¸
3¡¢charging source£ºAC 176V~264V£¬frequency 45-55Hz
4. Checking scope and resolution ratio of device:

5. Intrinsic Error
¡¡ ratio £¼0.03%
¡¡ Angle accuracy£¼¡À1¡ä
¡¡ Electric conductance£º¡À£¨1%
reading of electric conductance +1% reading of electric
¡¡ ¡¡
¡¡ susceptance + the last
number£©mS
¡¡ Electric susceptance£º¡À£¨1%
reading of electric conductance +1% reading of electric
¡¡ ¡¡
¡¡ susceptance + the last
number£©mS
6. Insulation
¡¡ The insulated resistor
of voltage and current input ends against the cover
¡Ý100M¦¸
¡¡ The frequency between
input electric source end and the cover is 2KV (valid),
being
tested for 1 minute.
7. Working time of battery: more then 6 hours in
full charged.
8. Cubage: main machine 40¡Á36¡Á14cm extension machine:
32¡Á28¡Á14cm
9. Weight: main machine 5kg extension machine: 3kg |
|
|
|
|
|
|