Products
Kehui Electric Appliances·Service power
YTLQ10-XX 10Kv airtight three-phase AC current sensor
YTLQ10-XX series current sensors detect current based on LPCT principle, three-phase integrated structure, epoxy resin casting, fully enclosed insulation, safe and reliable, suitable for common box outdoor pole-mounted circuit breakers with good anti-condensation performance (ZW20) Or outdoor pole-mounted load switch (FZW28) installation, suitable for current measurement (metering) and protection in AC 50/60Hz lines with the highest voltage of 12kV and below.
Key words:
Kehui
Three Phase Current Sensor
current sensor
Epoxy casting
Classification:

Enquiry hotline:

Email:
YTLQ10-XX 10Kv airtight three-phase AC current sensor
1. Introduction:
YTLQ10-XX series current sensors detect current based on LPCT principle, three-phase integrated structure, epoxy resin casting, fully enclosed insulation, safe and reliable, suitable for common box outdoor pole-mounted circuit breakers with good anti-condensation performance (ZW20) Or outdoor pole-mounted load switch (FZW28) installation, suitable for current measurement (metering) and protection in AC 50/60Hz lines with the highest voltage of 12kV and below.
Product naming rules:
2. Product Features:
YTLQ10-XX series current sensors are based on the principle of low-power coils. Compared with traditional transformers, they have the following advantages:
1. Integrates 3 phase current and 1 zero-sequence current sensors, small in size, light in weight, easy to install and use
2,. The secondary output is a safe low-voltage signal, without the risk of secondary open-circuit high voltage, increasing safety
3. The power consumption is greatly reduced and the heat generation is small
4. Standardized products, simplified selection and ordering process, and fast delivery
3. Implementation and Reference Standards
3.1. T/CES 018-2018 Specifications for 10kV and 20kV AC Sensors in Distribution Networks
3.2. GB/T 20840.8-2007 Transformers Part 8: Electronic current transformers
3.3.IEC-60044-8 electronic current transformer
4. Basic parameters
Temperature range: -40℃~+70℃
Rated primary current: phase sequence 600A, zero sequence 20A
Rated secondary voltage: phase sequence 1V, zero sequence 0.2V
Basic accuracy: phase sequence: 0.5S/5P10, zero sequence: 1S/10P10
Comprehensive impedance: 20kΩ
Rated continuous thermal current: 720A
Short-time thermal current: 25kA/4s
Dynamic current: 63kA
Secondary terminal ground withstand voltage: 3kV (1min)
5. Structural parameters
5.1. Structural dimensions
5.2. Test report
Pre
ZW32I-12T630 deep fusion pole-mounted circuit breaker
Related products
INQUIRY